Hydril Pulsation Dampener Manual

Installation and Operation Manual Chargeable Dampener Models Dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen) from a system fluid in the lower chamber. Depending on how dampeners are configured, they are used as Pulsation Dampeners, Inlet Stabilizers. TenarisHydril running manual Product EXPLORE 'Running Manual, runningmanual, running guidelines, guidelines' Wedge 623® Product EXPLORE 'wedge 623, wedge 623 connection, integral semi-flush, premium, intermediate casing, production casing, liners, tie-backs, dopeless, 600, integral semiflush, tsh wedge 623, wedge623, premium connection'. Created Date: 10/8/2009 2:26:55 PM.

  1. Hydril K20-7500 Pulsation Dampener Manual
  2. Hydril Pulsation Distributor
  3. Hydril K20 Pulsation Dampener Manual
  4. Hydril Pulsation Dampener Manual Instructions
  5. Pulsation Dampers For Pumps Pdf

Hydril K20-7500 Pulsation Dampener Manual

ManualPulsation

KEY FEATURES Hydril IP pulsation dampeners extend the life and increase the efficiency of suction, discharge and hydraulic flow system lines. Built for industrial and production applications, the non-wetted shell design reduces maintenance require- ments while accommodating corrosive process liquids. Hydril Type “K” Pulsation Dampener: Popular Mud Pump Spare Parts: Below is a partial list of mud pump spares, mud pump replacement parts, and mud pump parts that we have available. Fluid End Discharge Module Fluid End Studs & Nuts Full Open Valves Gardner Denver Lower Valve Guide Gland Brass And Junk Rings Gland Nut Ideco Mm-700 Duplex.

Hydril Pulsation Distributor

SFU Series

  1. SFU o-ring
  2. SFU wing nut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case

SFV & SFVM Series

Pulsation
  1. 6″ or 8″ suction gasket
  2. 6″ or 8″ grooved coupling
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case

SFT Series

  1. HPG-1 gasket (Nitrile or EPDM)
  2. Dust cap
  3. Loading valve
  4. Bleeder valve
  5. Cartridge
  6. Case

SFM Series

Hydril K20 Pulsation Dampener Manual

  1. SFM o-rings (2 required)
  2. SFM wingnut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case
  8. SFM wingnut screw

CHARGE TO 80%- 90% OF SUCTION PRESSURE OR THE MAXIMUM CHARGE PRESSURE OF THE CARTRIDGE, WHICHEVER IS LESS. THIS IS ONLY AN APPROXIMATION.

(YOU MAY FIND IT NECESSARY TO DECREASE THE PRESSURE IN THE SUCTION CARTRIDGE TO ACHIEVE OPTIMUM PUMP PERFORMANCE.)

  1. Shut down pump and relieve line pressure from discharge side before closing suction valve. After discharge line is relieved of pressure, close suction line valve and drain suction line.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY, charge the cartridge through loading valve ’C’ to the recommended operating pressure (90% of suction pressure). (DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE).
  7. Tighten safety nut ’D’ on loading valve ’C’.
  8. Replace loading valve protector cap ’B’
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.
  1. Shut down pump and relieve line pressure.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY charge the cartridge through loading valve ’C’ to correct charge pressure (use chart below).
    NOTE: DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE (ON CASE LABEL).
  7. Tighten safety nut ’D’ on loading valve ’C’ and replace cap.
  8. Replace loading valve protector cap ’B’.
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.

WARNING

Hydril Pulsation Dampener Manual

THE USE OF ANY GAS OTHER THAN NITROGEN IS EXTREMELY DANGEROUS.

NEVER ATTEMPT TO CHARGE OR PRE-CHARGE A CARTRIDGE OUTSIDE OF THE PULSATION STABILIZER CASE.

FOR PROPER CHARGING PROCEDURES REFER TO THE SUCTION OR DISCHARGE CHARGING GUIDE.

SFU Series

  1. SFU o-ring
  2. SFU wing nut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case

SFV & SFVM Series

  1. 6″ or 8″ suction gasket
  2. 6″ or 8″ grooved coupling
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case

SFT Series

  1. HPG-1 gasket (Nitrile or EPDM)
  2. Dust cap
  3. Loading valve
  4. Bleeder valve
  5. Cartridge
  6. Case

SFM Series

  1. SFM o-rings (2 required)
  2. SFM wingnut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case
  8. SFM wingnut screw

CHARGE TO 80%- 90% OF SUCTION PRESSURE OR THE MAXIMUM CHARGE PRESSURE OF THE CARTRIDGE, WHICHEVER IS LESS. THIS IS ONLY AN APPROXIMATION.

(YOU MAY FIND IT NECESSARY TO DECREASE THE PRESSURE IN THE SUCTION CARTRIDGE TO ACHIEVE OPTIMUM PUMP PERFORMANCE.)

  1. Shut down pump and relieve line pressure from discharge side before closing suction valve. After discharge line is relieved of pressure, close suction line valve and drain suction line.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY, charge the cartridge through loading valve ’C’ to the recommended operating pressure (90% of suction pressure). (DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE).
  7. Tighten safety nut ’D’ on loading valve ’C’.
  8. Replace loading valve protector cap ’B’
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.
  1. Shut down pump and relieve line pressure.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY charge the cartridge through loading valve ’C’ to correct charge pressure (use chart below).
    NOTE: DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE (ON CASE LABEL).
  7. Tighten safety nut ’D’ on loading valve ’C’ and replace cap.
  8. Replace loading valve protector cap ’B’.
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.

WARNING

THE USE OF ANY GAS OTHER THAN NITROGEN IS EXTREMELY DANGEROUS.

Hydril Pulsation Dampener Manual Instructions

NEVER ATTEMPT TO CHARGE OR PRE-CHARGE A CARTRIDGE OUTSIDE OF THE PULSATION STABILIZER CASE.

Pulsation Dampers For Pumps Pdf

FOR PROPER CHARGING PROCEDURES REFER TO THE SUCTION OR DISCHARGE CHARGING GUIDE.